Set a compensation coefficient for reducing a control error in the reduction of a corner roundness
and arch radius.
The larger the setup value, the smaller the theoretical error will be . However, since the speed at the
corner will go down, the cycle time will be extended.
Coefficient = 100 - setting value
(Note) This is valid when "#8021 COMP CHANGE" is set to "0".