P920 No spec: 3D coord conv
Details There is no specification for 3-dimensional coordinate conversion.
Remedy - Check the specifications.
P921 Illegal G code at 3D coord
Details The commanded G code cannot be performed during 3-dimensional coordinate conversion
modal.
Remedy - Refer to "MITSUBISHI CNC 700/70 Series Programming Manual (Machining Center Sys-
tem)" for usable G commands.
- When the basic specification parameter "#1229 set01/bit3 (Initial constant surface speed)"
is enabled, disable the parameter or issue the constant surface speed control cancel (G97)
command.
P922 Illegal mode at 3D coord
Details A 3-dimensional coordinate conversion command was issued during a modal for which 3-di-
mensional coordinate conversion cannot be performed.
Remedy - Refer to "MITSUBISHI CNC 700/70 Series Programming Manual (Machining Center Sys-
tem)" for usable G commands.
P923 Illegal addr in 3D coord blk