資料介紹:
2.5 Connection of power supply connector
Use the dedicated built-in power connector to supply power to the main unit.
Power should be supplied to the main unit, FX2NC Series input extension blocks. Perform crossover wiring using two (upper and lower) power
connectors for Input extension blocks.
Power Cable types "A" and "B" are supplied with the main unit, while type "C" is supplied with the input extension blocks.
Main unit
Input extension block
Input extension block
Input extension block
Output extension block
Resin
cover
3 Ground
(Green)
1 (Red)
Main unit
2 (Black)
1 (Red)
2 (Black)
The figure below shows the pin
numbers of the power connectors.
Two power connectors of each input extension
block are connected in parallel inside the block.
Accordingly, there is no discrimination between
the entrance side and the exit side of the
power supply. Either (upper or lower)
connector can be connected.
At shipment from the factory, a resin cover is
attached to the lower connector. Connect the
upper connector first. Remove the resin cover
from the lower connector when performing
crossover wiring for the later block.
Black
Black
Red
Red
Green
Ground
Removal of the power cable
1) Turn the power supply
OFF.
2) Pinch the power cable
connector "A" and
disconnect
it in the direction of the
arrow
(see figure on the right).
Press here
A
FX3UC-32MT-LT-2